Skip to content

Synchronizing scopes manually

If automatic synchronization is not enabled for the scopes that are used for web content, or if you want to run synchronization outside of a scheduled synchronization period, you can manually start the synchronization process.

  1. To manually run synchronization, run the cp-sync configuration task or submit an XML request to the portal by using the XML configuration interface.

    • To run synchronization with a configuration task, run the following task from the wp_profile_root/ConfigEngine directory:

      • Windows™: ConfigEngine.bat cp-sync -DWasPassword=password -DPortalAdminPwd=password
      • UNIX™Linux™: ./ConfigEngine.sh cp-sync -DWasPassword=password -DPortalAdminPwd=password
    • Create an XML request file and submit it using the xmlaccess command. Here is an example of a request you can use to start synchronization:

      <?xml version="1.0" encoding="UTF-8"?> 
      <request type="update" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" 
        xsi:noNamespaceSchemaLocation="PortalConfig_8.5.0.xsd"> 
        <portal action="locate"> 
          <task action="create" name="com.ibm.portal.cp.SynchronizationTask"/> 
        </portal> 
      </request>
      